The watch timing machine TYMC multifunction timegrapher MTG-3000 is a semi-professional model, offering various
functions to analyse a mechanical watch movement.
This model features a big, high resolution backlit LCD screen with 4 different display modes. It measures beat rate,
beat error, beat number and amplitude.
It stores 2048 beats and offers a "PAUSE" and "SHIFT“ function to pause measuring and view the previous 2048 beats.
Furthermore this model comes up with a programmed test mode:
The watch can be tested for a defined time in up to 6 positions (positions for measuring can be selected). After comple -
tion of the test program, the test results are displayed as a test report including beat rate, beat error and amplitude
in each single position. It also renders the maximum difference of the beat rate and amplitude of the 6 positions.
With the available optional printer (THERMOPRINT) the graphic and numeric results of all measurements and the
result of the programmed test can be printed.
pictures
The TYMC multifunction timegrapher MTG-3000 watch timing machine and the 6 position microphone (click to enlarge):
The single displays of the MTG-3000 (click to enlarge)
functions
measuring of beat rate [s/d]
measuring of beat error [ms]
automatic beat number detection (can also be set manually)
Signal gain control:
the basic gain of the input signal is adjusted automatically.
The level can also be adjusted manually for movements with very strong or weak signal
Beat numbers:
18.000, 19.800, 21.600, 25.200, 28.800 and 36.000 a/h
automatic detection or manual setting
Beat rate:
numeric display in s/d and diagramm
range: +/- 300 s/d
resolution: 1 s/d
accuracy: +/- 1s/d
Beat error:
numeric display in s/d and diagramm
range: 0.0 ms – 4.0 ms
resolution: 0.1 ms
accuracy: +/- 0.1 ms
Amplitude:
numeric display in degrees °
range: 90° - 350°
resolution: 1°
accuracy: +/- 3°
lift angle adjustable form 30° to 60° / resolution: 0.1°
6 position programmed test mode:
selectable positions: 1-6
measuring time per position: 10-50 s
displayed test results:
beat rate, beat error, amplitude of each single position,
maximum difference of beat rate and amplitude within the
tested positions
„Pause“ function to stop the measuring and view the
previous 2048 stored beats.
Time base:
XO
stability: +/- 0,3 s/d
Case:
dimensions: 240 x 160 x 100 mm
weight: ca. 0,8 kg (without power supply andmicrophone)
Power supply:
external power supply
90V – 240V AC 50-60Hz
Connectivities:
Thermal direct printer THERMOPRINT (available optionally):
Printing of graphic or numeric results of themeasuring
Printing the test result of the programmed test mode
Automatic microphon AUTOMIC-1 (available optionally):
stepper motor driven automatic microphone